dc.description.abstract | Environmental issues and sustainable development have guided the growth of cities. Sustainability in civil construction has major challenges in the industrial construction sector. One of the biggest is related to energy efficiency, that is, the industrial sector needs to efficiently reduce the environmental impact by seeking to use sustainable practices to reduce the use of fossil resources, allowing full recyclability, compliance with quality standards, energy efficiency combined with approaches aimed at technological evolution, economic and social development. The vertical fence along with the floor and roof are responsible for the interaction between the internal and external environments of the building to which it is inserted. Among these elements, the facade has fundamental importance and relevance in the constructive system, mainly because it is a great receiver of solar insolation. The objective of this work is to evaluate the heat transfer in prisms composed of concrete blocks (structural and solid cellular) with plaster internal coatings. The methodology of this research consists of making 02 prisms of blocks built from structural concrete blocks and solid blocks of cellular concrete. The composites received an external render with industrialized mortar 2.5 cm thick. In addition, new layers of plaster were added to the inside of the walls with different configurations of thicknesses of 1, 1.5 and 2.0 cm. Thus, prisms with different apparent mass densities were made for the study of heat transfer. For this to be possible, an active artificial condition was used as a source of study with continuous heat flow on the outside of the prism with temperature variations around 65 ± 2°C, focusing on the walls to evaluate the temperature conditions during 4 h of tests and later, determine the heat flux. In this way, the heat transfer values that were obtained in the tests of the prisms with and without coatings point to a greater thermal flux in the composition of the prism formed by structural concrete blocks - BCE without coating and a smaller thermal flux in the composite formed by blocks of cellular concrete - BCC with external coating composed of 0.5 cm of roughcast plus 2.0 cm of plaster. In the evaluations of the prisms with internal coating, the results showed that the heat transfer decreases when there was an increase in the thickness of the internal plaster coatings. The BCC prism with 2.0 cm thick internal plaster coating presented a lower thermal flux, when compared to the BCC prism with plaster coatings with thicknesses of 1.0 and 1.5 cm respectively. When the BCE prism had a smaller internal coating thickness, it obtained a higher heat flux value. Experimental studies have shown a significant reduction the internal temperature of the BCE prism around 2.82 °C, when a layer of 1.0 cm of plaster was added. In another expressive result, there was an excellent reduction of 3.13 °C in relation to the internal thickness of 2.0 cm of plaster and of 4.33 °C, the best result obtained, when there was an increment of the external ceramic coating plus 2, 0 cm of internal plaster. The BCC prisms showed a good reduction in the internal temperature, an average of 1.4 °C between the plaster layers with thicknesses of 1, 1.5 and 2.0 cm, however the best result occurred in the comparison between the BCC prism with 1, 0 cm related to the prism with a thickness of 2.0 cm of plaster plus external ceramic coating, there was a difference of 3.6 °C, obtaining a very relevant and satisfactory value for the research. Finally, the main thermal performance parameters were calculated: resistance, transmittance, capacity and thermal delay, according to NBR 15220 (ABNT, 2005). The thermal capacity found in the BCE and BCC prisms was compatible with the value suggested by the thermal performance standard, except for the uncoated BCC prism, which presented a lower value. The tests with infrared thermography allowed the qualitative analysis of heat transfer and temperature variations | pt_BR |
dc.format.extent | 93p. | pt_BR |
dc.language | pt_BR | pt_BR |
dc.publisher | Instituto Federal de Educação, Ciência e Tecnologia de Pernambuco | pt_BR |
dc.rights | Acesso Aberto | pt_BR |
dc.rights | An error occurred on the license name. | * |
dc.rights | An error occurred on the license name. | * |
dc.rights.uri | An error occurred getting the license - uri. | * |
dc.rights.uri | An error occurred getting the license - uri. | * |
dc.subject | Blocos de concreto | pt_BR |
dc.subject | transferência de calor | pt_BR |
dc.subject | termografia infravermelha | pt_BR |
dc.subject | Gestão Ambiental | pt_BR |
dc.title | Análise de transferência de calor em prisma composto por blocos de concreto com revestimento interno de gesso: subsídios para construções sustentáveis | pt_BR |
dc.type | dissertacao | pt_BR |
dc.creator.Lattes | https://lattes.cnpq.br/4043067402742269 | pt_BR |
dc.contributor.advisor1 | Silva, Ronaldo Faustino da | |
dc.contributor.advisor1Lattes | http://lattes.cnpq.br/7265569987870357 | pt_BR |
dc.contributor.advisor-co1 | Carvalho, Renata Maria Caminha Mendes de Oliveira | |
dc.contributor.advisor-co1Lattes | http://lattes.cnpq.br/4312346687923790 | pt_BR |
dc.contributor.referee1 | Mota, João Manoel de F. | |
dc.contributor.referee2 | Silva, Hernande Pereira da | |
dc.contributor.referee3 | Oliveira, Romilde Almeida de | |
dc.contributor.referee1Lattes | http://lattes.cnpq.br/7401710771055096 | pt_BR |
dc.contributor.referee2Lattes | http://lattes.cnpq.br/1800835100486343 | pt_BR |
dc.contributor.referee3Lattes | http://lattes.cnpq.br/9272579827887449 | pt_BR |
dc.publisher.initials | IFPE | pt_BR |
dc.publisher.department | Recife | pt_BR |
dc.publisher.program | Programa de Mestrado Profissional em Gestão Ambiental | pt_BR |
dc.publisher.country | Brasil | pt_BR |
dc.subject.cnpq | ENGENHARIAS::ENGENHARIA CIVIL::CONSTRUCAO CIVIL::MATERIAIS E COMPONENTES DE CONSTRUCAO | pt_BR |
dc.description.resumo | As questões ambientais e o desenvolvimento sustentável têm pautado o crescimento das cidades. A sustentabilidade na construção civil possui grandes desafios no segmento industrial da construção. Um dos maiores está relacionado à eficiência energética, ou seja, o setor industrial precisa reduzir, de forma eficiente, o impacto ambiental, buscando utilizar práticas sustentáveis, e com isso reduzir o uso de recursos de origem fóssil, permitindo a plena reciclabilidade, a conformidade com os padrões de qualidade, a eficiência energética combinadas com abordagens voltadas à evolução tecnológica, desenvolvimento econômico e social. A vedação vertical junto com o piso e a cobertura são responsáveis pela interação entre os ambientes internos e externos da edificação aos quais estão inseridos. Dentre esses elementos, a fachada possui fundamental importância e relevância no sistema construtivo, principalmente por ser grande receptor de insolação solar. O objetivo deste trabalho é avaliar a transferência de calor em prismas compostos por blocos de concreto (estrutural e celular maciço) com revestimentos internos de gesso. A metodologia desta pesquisa consiste na confecção de 02 prismas de blocos, construídos a partir de blocos de concreto estrutural e de blocos maciços de concreto celular. Os compósitos receberam um reboco externo com argamassa industrializada com 2,5 cm de espessura. Ademais, foram acrescidos na parte interna das paredes novas camadas de revestimento de gesso com diferentes configurações de espessuras 1, 1,5 e 2,0 cm. Assim, foram confeccionados os prismas com diferentes densidades de massa aparente para estudo da transferência de calor. Para que isso fosse possível, utilizou-se como fonte de estudo uma condição artificial ativa com fluxo de calor contínuo na parte externa do prisma com variações de temperaturas em torno de 65 ± 2°C, incidindo sobre as paredes para avaliar as condições de temperaturas durante 4 h de ensaios e posteriormente, determinar o fluxo de calor. Dessa forma, os valores de transferência de calor que foram obtidos nos testes dos prismas com e sem revestimentos apontam um maior fluxo térmico na composição do prisma formado por blocos de concreto estrutural- BCE sem revestimento e um menor fluxo termal no compósito formado por blocos de concreto celular - BCC com revestimento externo composto por 0,5 cm de chapisco mais 2,0 cm de emboço. Nas avalições dos prismas com revestimento interno, os resultados demostraram que, a transferência de calor diminui quando houve um aumento das espessuras dos revestimentos internos de gesso. O prisma BCC com revestimento interno de gesso com 2,0 cm de espessura, apresentou um menor fluxo térmico, quando comparado com o prisma BCC com revestimentos de gesso com espessuras de 1,0 e 1,5 cm, respectivamente. O prisma BCE quando possuiu uma menor espessura interna de revestimento, obteve um valor maior de fluxo de calor. Os estudos experimentais demostraram uma significativa redução na temperatura interna no prisma BCE por volta de 2,82 °C, quando houve a adição da camada de 1,0 cm de gesso. Em outro resultado expressivo, houve uma excelente redução de 3,13 °C com relação à espessura interna de 2,0 cm de gesso e de 4,33 °C, melhor resultado obtido, quando houve o incremento do revestimento cerâmico externo mais 2,0 cm de gesso interno. Os prismas BCC demostraram boa redução na temperatura interna, em média de 1,4 °C entre as camadas de gesso com espessuras 1, 1,5 e 2,0 cm, entretanto o melhor resultado ocorreu na comparação entre o prisma BCC com 1,0 cm relacionado com o prisma com espessura de 2,0 cm de gesso, mais revestimento cerâmico externo, houve uma diferença de 3,6 °C, obtendo valor muito relevante e satisfatório para a pesquisa. Por fim, foram calculados os principais parâmetros de desempenho térmico: resistência, transmitância, capacidade e atraso térmico, conforme a NBR 15220 (ABNT, 2005). A capacidade térmica encontrada nos prismas BCE e BCC foi compatível com o valor sugerido pela norma de desempenho térmico, exceto no prisma BCC sem revestimento que apresentou valor abaixo. Os ensaios com termografia infravermelha permitiram analisar a transferência do calor qualitativamente e as variações de temperaturas. | pt_BR |
dc.degree.level | mestrado | pt_BR |